fejlec

Fire extinguishers

Maxima PKM 1A

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/63/2009

IS-ÉMI-TÜV-09-11-KJZ-001

IS-ÉMI-TÜV-09-11-KJZ-002

5A; 34B; C

330 mm

100 mm

85 mm

2 kg

ISOCONP ABC 80

1 kg

Nitrogen

>6 s

15 bar

27 bar

From -20 °C to +60 °C

1kg porral oltó


Maxima PKM 2A

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/54/2009

IS-ÉMI-TÜV-09-11-KJZ-001

IS-ÉMI-TÜV-09-11-KJZ-002

13A; 89B; C

375 mm

110 mm

110 mm

3,6 kg

ISOCONP ABC 80

2 kg

Nitrogen

>9 s

15 bar

27 bar

From -20 °C to +60 °C

2kg porral oltó


Maxima PKM 4A

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/64/2009

IS-ÉMI-TÜV-09-11-KJZ-001

IS-ÉMI-TÜV-09-11-KJZ-002

21A; 144B; C

495 mm

280 mm

140 mm

6,9 kg

ISOCONP ABC 80

4 kg

Nitrogen

>12 s

15 bar

27 bar

From -20 °C to +60 °C

4kg porral oltó


Maxima PKM 6A

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/55/2009

IS-ÉMI-TÜV-09-11-KJZ-001

IS-ÉMI-TÜV-09-11-KJZ-002

43A; 233B; C

530 mm

270 mm

160 mm

9,8 kg

ISOCONP ABC 80

6 kg

Nitrogen

>15 s

15 bar

27 bar

From -20 °C to +60 °C

6kg porral oltó


Maxima PKM 6B

MSZ EN 3 approval

CE 0036 - (PED)

Tested extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Operating period

Working pressure

Test pressure

Operating temperature range

TVL 660/65/2009

IS-ÉMI-TÜV-09-11-KJZ-007

IS-ÉMI-TÜV-09-11-KJZ-008

34A; 144B; C

515 mm

270 mm

160 mm

9,8 kg

ISOCONP ABC 50

6 kg

Nitrogén

>15 s

15 bar

27 bar

-20 °C +60 °C

6kg porral oltó


Maxima PKM 12A

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/66/2009

IS-ÉMI-TÜV-09-11-KJZ-001

IS-ÉMI-TÜV-09-11-KJZ-002

55A; 233B; C

610 mm

320 mm

184 mm

17,1 kg

ISOCONP ABC 80

12 kg

Nitrogen

>15 s

15 bar

27 bar

From -20 °C to +60 °C

12kg porral oltó


Maxima PKM 50A

MSZ EN 1866 - MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/56/2009

IS-ÉMI-TÜV-09-11-KJZ-005

IS-ÉMI-TÜV-09-11-KJZ-006

A; III B; C

1100 mm

469 mm

310 mm

80 kg

ISOCONP ABC 80

50 kg

Nitrogen

>50 s

15 bar

26 bar

From -20 °C to +60 °C

50kg-os porral oltó


Maxima HKM 6

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/67/2009

IS-ÉMI-TÜV-09-11-KJZ-003

IS-ÉMI-TÜV-09-11-KJZ-004

21A; 144B;

545 mm

300 mm

162 mm

10,3 kg

3% AFFF C-301MS

6 liter

Nitrogen

>15 s

15 bar

26 bar

From +4°C to +60 °C

6l-es habbal oltó


Maxima HKM 9

MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/68/2009

IS-ÉMI-TÜV-09-11-KJZ-003

IS-ÉMI-TÜV-09-11-KJZ-004

27A; 183B;

610 mm

320 mm

184 mm

14,2 kg

3% AFFF C-301MS

9 liter

Nitrogen

>17 s

15 bar

26 bar

From +4°C to +60 °C

9l-es habbal oltó


Maxima HKM 50

MSZ EN 1866 - MSZ EN 3 approval

CE 0036 - (PED)

Working extinguishing performance

Gross high

Gross width

Cylinder diameter

Gross weight

Extinguishing substance

Extinguishing charge

Fuel substance

Működési idő

Working pressure

Test pressure

Operating temperature range

TVL 660/71/2009

IS-ÉMI-TÜV-09-11-KJZ-005

IS-ÉMI-TÜV-09-11-KJZ-006

A; B

1100 mm

469 mm

310 mm

~80 kg

3% AFFF C-301MS

50 liter

Nitrogen

>40 s

15 bar

26 bar

From 0°C to +60 °C

50l-es habbal oltó


Maxima CKM 2

MSZ EN 3 approval

Tested extinguishing performance

Gross high

Gross width

Gross weight

Extinguishing substance

Extinguishing charge

Effective range

Cylinder material

Working pressure(+20°C)

Test pressure (bar)

Operating temperature range

TVL 660/69/2009

34B, C

610 mm

260 mm

8 kg

Carbon dioxide

2 kg

5-7 m

Carbon steel

50 bar

250 bar

From -20 °C to +60 °C

2kg-os széndioxiddal oltó


Maxima CKM 5

MSZ EN 3 approval

Tested extinguishing performance

Gross high

Gross width

Gross weight

Extinguishing substance

Extinguishing charge

Effective range

Cylinder material

Working pressure(+20°C)

Test pressure (bar)

Operating temperature range

TVL 660/70/2009

89B, C

930 mm

440 mm

17 kg

Carbon dioxide

5 kg

5-7 m

Carbon steel

50 bar

250 bar

From -20 °C to +60 °C

5kg-os széndioxiddal oltó


fejlec